Lamp life: Push (ENTER) for more then 5 seconds.
Lamp life reset: Push (-), (+) and (ENTER) simultaneously until you get the zero setting of the
display to reset the lamp life meter.
Use meter: Push (ENTER) for more than 15 seconds.
4.3 DMX standard mode
Make sure the display of the unit is correctly set. The ACROBAT PE 575 unit uses from a
minimum of 9 up to a maximum of 14 channels depending on the number of options selected.
The DMX addressing of more units accessed by a digital controller should be set as per follo-
wing diagram.
13
1= PAN/TILT Swap
2= PAN Reverse
3= TILT Reverse
4= Automatic/Master
5= PAN/TILT low speed
6= Automatic mode through DMX
7= Fixed - colour position
8= PAN/TILT 16 bit
9= TEST/DEMO mode
10= Display readout reversal
11= Lamp ON/OFF through DMX
12= Stand-By activation through DMX
13= Display ON/OFF
14=PAN/TILT positioning correction system ON/OFF
Address
9 Channels
Projector 1
0 0 1
Projector 2
0 1 0
Projector 3
0 1 9
Projector 4
0 2 8
Projector 5
0 3 7
Projector 6
0 4 6
Projector 7
0 5 5
Projector 8
0 6 4
Projector 9
0 7 3
Projector 10
0 8 2