8 Technical Reference
8.1 Application limits
Data
Description
Media (liquid) temperature
Maximum 40°C (104°F)
pH of the pumped media (liquid)
2–10
Media (liquid) density
1100 kg/m³ (9.2 lb per US gal)
maximum
Depth of immersion
Maximum 20 m (65 ft)
Other
For the specific weight, current,
voltage, power ratings, and speed of
the pump, see the data plate of the
pump.
For other applications, contact a sales
or authorized service representative for
information.
8.2 Motor data
Feature
Description
Motor type
Squirrel-cage induction motor
Frequency
50 Hz or 60 Hz
Supply
3-phase
Starting method
Direct on-line
Star-delta
Maximum starts
per hour
30 evenly-spaced starts per hour
Code compliance
IEC 60034-1
Voltage variation
without
overheating
±10%, if it does not run continuously at full load
Voltage imbalance
tolerance
2%
Maximum
frequency
variation (for
pumps with
SMART
™
)
±3 Hz
Stator insulation
class
F (155°C [311°F])
Motor encapsulation
Motor encapsulation is in accordance with IP68.