![Grindex 8120.280 Sandy Inox Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/grindex/8120-280-sandy-inox/8120-280-sandy-inox_installation-operation-and-maintenance-manual_2265326020.webp)
WS004313F
Screened SUBCAB
T
1
T
2
T
3
T
4
Figure 2: Aluminum foil on the control element.
c) Put a white shrink hose over the drain wire.
d) Twist T1+T2 and T3+T4.
e) Put a shrink hose over the control element.
Make sure that the conductive aluminum foil and drain wire are covered.
3. Prepare the ground (earth) core of the SUBCAB
™
cable:
a) Peel the yellow-green insulation from the ground (earth) core.
b) Check that the ground (earth) core is at least 10% longer than the phase
cores in the cabinet.
c) If applicable, put a cable lug on the ground core.
4. Prepare the ground (earth) core of the screened SUBCAB
™
cable:
a) Untwist the screens around the power cores.
b) Twist all power core screens together to create a ground (earth) core.
c) Put a yellow-green shrink hose over the ground (earth) core.
Leave a short piece uncovered.
d) Check that the connected ground (earth) core has sufficient slack. The
core must stay connected even if the power cores are pulled loose.
5. Prepare the power cores:
a) Remove the aluminum foil around each power core.
b) Peel the insulation from each power core.
6. Prepare the ends of the ground (earth) core, the power cores, and the drain
wire:
Connection type
Action
Screw
Fit cable lugs to the ends.
Terminal block
Fit end sleeves or leave the ends as they are.
4.4.5 Connect the motor cable to the pump
NOTICE:
Leakage into the electrical parts can cause damaged equipment or a blown fuse.
Keep the end of the motor cable dry at all times.
1. Check the data plate to see which connections are required for the power
supply.
2. Connect the motor cable conductors, including ground (earth), to the terminal
or starter unit.
3. Make sure that the pump is correctly connected to ground (earth).
4. Tighten the cable entry into its bottom-most position.
The seal sleeve and the washers must conform to the outside diameter of the
cables.
4 Installation
18
8120.280 Sandy Inox Installation, Operation, and Maintenance Manual
Содержание 8120.280 Sandy Inox
Страница 1: ...www grindex com Installation Operation and Maintenance Manual 8120 280 Sandy Inox ...
Страница 2: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......