CAUTION: Crush Hazard
The starting jerk can be powerful. Make sure nobody is close to the unit when it
is started.
The correct direction of impeller rotation is clockwise when you look at the pump
from above. When started, the pump will react in the opposite direction to the
impeller rotation.
L2
L1
L2
L3
L3
L1
WS001397A
Figure 3: Start reaction
1. Connect the pump to power as follows:
Condition
Action
The pump has a CEE plug with
internal phase shifter.
Connect the plug.
WS006205A
The pump has a phase shifter with an
on/off switch.
Turn the knob on the phase shifter in
either direction.
WS006207A
The pump has neither a CEE plug with
internal phase shifter, nor a phase
shifter with an on/off switch.
1. Connect the pump to power.
2. Switch on the power.
The pump should start. If it does not, then continue to the next step.
2. If the pump does not start and the fuses are correct, then shift two phases: