![Grindex 8120.280 Sandy Inox Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/grindex/8120-280-sandy-inox/8120-280-sandy-inox_installation-operation-and-maintenance-manual_2265326031.webp)
Service item
Action
Cable entry
1. Check that the following requirements are met:
– The cable clamps must be properly tightened.
– Standard pump version: The cable entry must be
firmly tightened into its bottom-most position.
– The seal sleeve and the washers must conform to the
outside diameter of the cables.
2. Cut off a piece of the cable so that the seal sleeve closes
around a new position on the cable.
3. Replace the seal sleeve, if necessary.
Inspection
volume
1
1. Remove the inspection screws.
a. Inner screw
b. Outer screw
2. Drain all liquid, if any.
3. If there is oil in the inspection volume, then empty the oil
and check again after one week. If there is oil in the
inspection volume again, then replace the mechanical
seal. Contact an authorized service shop.
4. If there is water in the inspection volume, then check
that the inspection screw O-ring is not damaged.
5. Check that the inspection screw is properly tightened.
Cable
1. If the outer jacket is damaged, then replace the cable.
2. Check that the cables do not have any sharp bends and
are not pinched.
Cooling system If the flow through the system has been partly restricted,
then rinse and clean.
Level sensors
or other sensor
equipment
1. Check the functionality.
2. Repair or replace any damaged equipment.
3. Clean and adjust the equipment.
Starter
equipment
1. Check the condition and functionality.
2. Contact an electrician, if necessary.
Insulation
resistance in
the stator
1. Check the insulation between:
– Phase–phase on the stator
– Phase–ground (earth)
The insulation should be > 1 megaohm. Use a 1000-VDC
megger to test the insulation.
2. If the resulting value is < 1 megaohm, then contact an
authorized service shop.
6.3.2 Overhaul
The basic repair kit includes O-rings, seals, and bearings.
For an overhaul, do the following in addition to the tasks listed under
Inspection.
Service item
Action
Support and main
bearing
Replace the bearings with new bearings.
Mechanical seal
Replace with new seal units.
1
Regardless of individual applications, the inspection volume should not be inspected less frequently than
the intervals for normal applications and operating conditions at media (liquid) temperatures <40°C
(104°F).
6 Maintenance
8120.280 Sandy Inox Installation, Operation, and Maintenance Manual
29