![Grindex 8120.280 Sandy Inox Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/grindex/8120-280-sandy-inox/8120-280-sandy-inox_installation-operation-and-maintenance-manual_2265326025.webp)
Condition
Action
The pump has a CEE plug with
internal phase shifter.
1. Pull out the plug.
2. Shift two phases.
3. Wait until the motor has stopped.
4. Connect the plug.
WS006206A
The pump has a phase shifter with an
on/off switch.
1. Turn the knob on the phase shifter
to neutral position.
2. Wait until the motor has stopped.
3. Turn the knob to the opposite
position from before.
WS006208A
The pump has neither a CEE plug with
internal phase shifter, nor a phase
shifter with an on/off switch.
Transpose two phase leads on the
output terminal of the starter.
NOTICE:
Do not reverse the phase sequence while the pump is running. Temporarily
incorrect rotation can occur, resulting in damage to motor electronics and
rotating parts.
The pump should start. If it does not, then contact a certified electrician to
check the mains and the junctions.