11
3.1.2. Sauna floor protection
Figure 3.
A) Concrete floor without finish
The heater can be installed on the floor without any special precautions, if the concrete
thickness is not less than 60 mm. There shall be no electrical cables, water supply and
sewage pipes in the concrete under the heater.
B) Floor with tile finish
The materials laid under the tiles, such as: glue, waterproofing and so on, are not resistant
to heat radiation of the heater. You can use special racks to protect the floor under the
heater.
C) Floor made of combustible materials.
You can use special racks to protect the floor under the heater or arrange an understructure
rack consisting of layers of heat-insulating, non-combustible, heat-reflecting materials of
sufficient thickness. In case the floor in front of the heater door is made of combustible
material, it is necessary to install floor protection made of non-combustible material.
IMPORTANT! Make sure that the floor is capable of withstanding the heater load. Take
measures, if necessary.
3.1.3. Safety distances
Figure 4, Table 2.
(A) -
Distance from the heater connection to the ceiling.
(B) -
Minimum safety distance to flammable materials on both sides of the heater,
(C) -
behind and
(D) -
in front of it.
(E) -
Distance to the walls made of non-combustible materials.
(F) -
Distance to the walls made of non-combustible materials in the alcove.
The gap between the heater and the walls made of non-combustible materials (E, F) is
necessary for air circulation.
А
�
50-100
Естественная вентиляция
B
Естественная вентиляция
B
50
0
А
�
50-100
А
�
50-100
Естественная вентиляция
B
Естественная вентиляция
B
50
0
А
�
50-100
Figure 2
.
Mechanical
exhaust
ventilation
Содержание Dubravo 180 Long
Страница 15: ...15 Figure 5 Stone chimney connection Figure 6 Steel chimney connection...
Страница 18: ...18 Dubravo 180 Window 790 940 650 600 450 115 460 180 570...
Страница 26: ...26 Notes...
Страница 27: ...27 Notes...