23
Door mini and Short/Long
The firebox door can be mounted in such
ways that it will open either to the right,
or to the left. To do so, you need to pull
out the metal pin, which attaches the
door, and carefully remove the metal
spacer installed under the door.
Further:
1) Choose the door opening direction
and mount the door onto the seat. The
spacer shall be installed on the hole
under the door.
2) Fix the door in this position via the
metal pin.
1
2
Door mini
Door Short/Long
application, subsequent cleaning of surfaces should be carried out in accordance with the
sealant application instruction. Procedure:
4.1) Apply the sealant from the rim side of the telescopic side along the whole length.
4.2) Fill the gap between the telescopic and fixed parts with the sealant while compacting
the sealant with an elastic applicator (for example, a rubber one) of a necessary size.
Note: in case the surface of the flue was not properly cleaned of leftover sealant after
application, then it can peel off after hardening and further heating of the furnace. Clean
with a plastic brush and waste cloth. Clean after complete cooldown of the heater.
Sealant
Telescopic part
Fixed part
Содержание Dubravo 180 Long
Страница 15: ...15 Figure 5 Stone chimney connection Figure 6 Steel chimney connection...
Страница 18: ...18 Dubravo 180 Window 790 940 650 600 450 115 460 180 570...
Страница 26: ...26 Notes...