22
Decorative screen / decorative screen Stone (assembly procedure)
Note: install the screen only after installation of the heater on the place of permanent
operation.
Procedure:
1) Match the mounting holes on the screen and on the heating flue frame;
2) Fix the screen with the self-tapping screws (included into the contents of delivery).
Telescopic heating flue
Note: correct installation of the telescopic part of the heating flue precludes air inflow
through the gap between flue parts, which allows maintaining the process of burning within
the prescribed limits
Procedure:
1) Unscrew the transport self-tapping screws in the upper part of the heating flue, take its
telescopic part out.
2) Install the heater on the place of
permanent operation.
3) Insert the telescopic part to the
necessary depth, while keeping the
telescopic part at least 50 mm inside the
fixed part.
4) Close the gap between the telescopic
and the fixed parts of the heating flue. As
a rule, a sealant for furnaces, fireplaces,
and chimneys with a maximum operating
temperature up to 1500 °C, but not less
than 700 °C is used for these purposes.
After sealant hardening, it is necessary to
avoid mechanical impact on the heating
flue parts and the seam, the sealant shall
notcrumble and crack. Surface treatment,
Содержание Dubravo 180 Long
Страница 15: ...15 Figure 5 Stone chimney connection Figure 6 Steel chimney connection...
Страница 18: ...18 Dubravo 180 Window 790 940 650 600 450 115 460 180 570...
Страница 26: ...26 Notes...