The manufacturer has set the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange
capacity, and gallon capacity. For water softeners the salt dose refill time has been preset.
The dealer
should read this page and guide the installer regarding hardness, day override, and time of
regeneration, before installation:
For the installer
, the following must be used:
• Set Installer Settings ... Hardness, Day Override (preset to 12 days), and Time of Regeneration
(preset to 2:00 a.m.)
• Read N
ormal
o
peratiNg
D
isplays
• Set t
ime
of
D
ay
• Read p
ower
l
oss
& e
rror
D
isplay
For the homeowner,
please read operating instructions and displays.
Water Softeners:
During operation, the normal user displays are
time
of
Day
or
galloNs
remaiNiNg
before regeneration will
occur.
D
ays
remaiNiNg
is an optional display but is not normally used. Each of these can be viewed by pressing
Next
to scroll through them. When stepping through any displays or programming, if no buttons are
pressed within 5-minutes, the display returns to a normal user display. Any changes made prior to the 5
minute time out are incorporated.
To quickly exit any Programming, Installer Settings, etc., press
set
clock
. Any changes made prior to the
exit are incorporated. If desired, two regenerations within 24 hours are possible with a return to the preset
program. To do a double regeneration:
1. Press the
regeN
button once.
regeN
toDay
will flash on the display.
2. Press and hold the
regeN
button for 3 seconds until a regeneration begins.
Once the valve has completed the immediate regeneration, the valve will regenerate one more time at the
preset.
b
yPass
V
alVe
:
The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure
in order to perform control valve repairs or maintenance. The 1” full flow bypass valve incorporates 4
positions including a diagnostic position that allows a service technician to have pressure to test a system
while providing untreated bypass water to the building.
Be sure to install bypass valve onto main control valve, before beginning plumbing. Or, make provisions in
the plumbing system for a bypass.
The bypass body and rotors are glass filled Noryl
®
and the nuts and caps are glass filled polypropylene.
All seals are self-lubricating EPDM to help prevent valve seizing after long periods of non-use. Internal “O”
Rings can easily be replaced if service is required.
The bypass consists of two interchangeable plug valves that are operated independently by red arrow
shaped handles. The handles identify the direction of flow. The plug valves enable the bypass valve to
operate in 4 positions.