background image

 Q

uiCk

 r

eferenCe

 g

uide

:

MANUAL REGENERATION

NOTE: For softeners, if brine 

tank does not contain salt, fill 

with salt and wait at least 2 

hours before regeneration. 

If you need to initiate a 

manual regeneration, either 

immediately, or the same 

night at the preprogrammed 

time for regeneration (typically 2:00 AM), complete the following steps. 

For Immediate Regeneration: Press and hold 

regen

 until valve motor 

starts (typically 3 seconds). 

For Regeneration the same night: Press and release 

regen

 (notice 

that flashing “REGEN TODAY” appears).

ERROR

If the display toggles between “Error” 

and an error code (i.e. a number), call 

a service technician and report the error 

code.

BYPASS VALVE OPERATION

To shut-off water to the system, please position arrow handles as shown 

in the bypass operation diagram below. If your valve doesn’t look like the 

diagram below, contact your service technician for instructions on how to 

shut off water.

NORMAL OPERATION

BYPASS OPERATION

TO SET TIME OF 

DAY

In the event of a prolonged 

power outage, time of day 

flashes, indicating that this  

needs to be reset. All other 

information will be stored 

in memory no matter how 

long the power outage. 

Please complete the steps 

as shown to the right. To 

access this mode, press  

set

 

clock

.

1.  Accessed by pressing 

set

 

clock

2.  Adjust hours with 

and buttons, AM/PM 

toggles at 12

3. Press 

next

4. Adjust minutes with 

  and buttons 

5.   Press 

next

 to complete 

and return to normal 

operation

1.  Accessed by pressing 

next

 and 

button 

simultaneously

2. Adjust hardness using 

   

and 

buttons

3. Press 

next

4.  Adjust days between 

regenerations using 

and 

buttons

5. Press 

next

6.  Adjust time of 

regeneration hour with 

and 

buttons, AM/

PM toggles at 12.

7. Press 

next

8.  Adjust time of 

regeneration minutes 

with 

and 

buttons

9.  Press 

next

 to complete 

and return to normal 

operation.

ADJUST HARDNESS, DAYS BETWEEN 

REGENERATION, OR TIME OF REGENERATION

For initial set-up or to 

make adjustments, please 

complete the steps as 

shown to the right. Access 

this mode by pressing

next

 and button  

simultaneously.

NOTE: Hardness display 

shows “-nA-” if used as  

a filter. If other displays 

do not appear, refer to 

manual.

Water Technologies

Water Technologies

Water Technologies

USA: 1270 Flagship Dr. Perrysburg, OH, 43551

Phone: 1-419-874-6770      Fax: 419-874-6769

Canada: 400 Southgate Dr Guelph, ON, N1G 4P5 

Phone

:1-888-5-WATER-0      

Fax

:519-837-8913

www.greenwaywt.com

REV05-18

GENERAL OPERATION

When the system is operating, one of three displays will be shown: Time of 

day, gallons of treated water available, or gallons per minute. Pressing 

next

 

will toggle between the three choices.

Содержание GACS1035

Страница 1: ...Water Technologies Water Technologies Water Technologies Installation Instructions Owner s Manual Advance Cabinet Series Softeners...

Страница 2: ...Solids Over 10ppm may be harmful for human consumption Water conditioners do not remove nitrates or coliform bacteria this requires specialized equipment Greenway Water Conditioners are precision bui...

Страница 3: ...the exit are incorporated If desired two regenerations within 24 hours are possible with a return to the preset program To do a double regeneration 1 Press the regen button once regen today will flas...

Страница 4: ...to the building while not allowing water to exit from the system to the building Fig 3 This allows the service technician to draw brine and perform other tests without the test water going to the buil...

Страница 5: ...be used to unscrew the nut or cap Do not use a pipe wrench to tighten nuts or caps Do not place screwdriver in slots on caps and or tap with a hammer SITE REQUIREMENTS water pressure 30 100 psi curre...

Страница 6: ...f the control valve form a 7 loop at the discharge end of the line so that the bottom of the loop is level with the drain connection on the control valve This will provide an adequate anti siphon trap...

Страница 7: ...ss as calcium carbonate per gallon using the s or t buttons The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon can be increased if soluble iron needs to...

Страница 8: ...amming cont d 3 Manual Regeneration Sometimes there is a need to regenerate the system sooner than when the system calls for it usually referred to as manual regeneration There may be a period of heav...

Страница 9: ...ne tank filling and at no time during this process will you be without treated water 4 Power Loss If the power goes out for less than two hours the system will automatically reset itself If an extende...

Страница 10: ...de Fig 3 on page 2 CAUTION If water flows too rapidly it could result in loss of media to the drain When the water is flowing steadily to the drain without the presence of air slowly open the inlet va...

Страница 11: ...ay be needed for correct operation 2 Iron removal may vary depending on form of iron pH and other local conditions On waters that are pre chlorinated or where other pre oxidation occurs an iron precip...

Страница 12: ...ation time option in programming E control set at NORMAL on 0 E check with regeneration time option in programming 5 Error followed by code Error code 1001 unable to recognize start of regeneration Er...

Страница 13: ...and PC board power B no power at outlet B restore power C broken drive gear or drive cap assy C replace gear or drive cap assy D defective PC board D replace board 8 Valve does not regenerate automati...

Страница 14: ...o Part No Description Qty 1 YY WS CV3005 Spacer stack assembly 1 2 YY WS CV3004 Drive cap assembly 1 3 YY WS CV3135 O ring 228 1 4a YY WS CV3011 Piston assembly downflow 1 4b YY WS CV3011 01 Piston as...

Страница 15: ...ng 013 lower The injector plug and the injector each use one lower and one upper o ring REFILL PORT ASSEMBLY Item No Part No Description Qty 1 YY WS CV3195 01 Refill port plug assembly 1 2 YY WS CH461...

Страница 16: ...CV3162 010 1 0 DLFC for 3 4 elbow YY WS CV3162 013 1 3 DLFC for 3 4 elbow YY WS CV3162 017 1 7 DLFC for 3 4 elbow YY WS CV3162 022 2 2 DLFC for 3 4 elbow YY WS CV3162 027 2 7 DLFC for 3 4 elbow YY WS...

Страница 17: ...3 01 Meter plug assembly 1 SAFETY FLOAT ASSEMBLY Item No Part No Description 1 YY WS CH4650 01 474 safety elbow 3 8 2 YY WS CH4655 474 5 gpm flow control 3 YY WS CH4615 Elbow locking clip 4 YY WS CH46...

Страница 18: ...connect 2 2 YY WS CV3150 Split ring 2 3 YY WS CV3105 O ring 215 2 4 YY WS CV3145 Bypass rotor 1 2 5 YY WS CV3146 Bypass cap 2 6 YY WS CV3147 Bypass handle 2 7 YY WS CV3148 Bypass rotor seal retainer...

Страница 19: ...WS CV3189 Fitting 2 1 BRASS SWEAT Item No Part No Description Qty YY WS CV3007 02 1 brass sweat assembly 2 1 YY WS CV3151 Nut 1 quick connect 2 2 YY WS CV3150 Split Ring 2 3 YY WS CV3105 O ring 215 2...

Страница 20: ...teps as shown to the right To access this mode press set clock 1 Accessed by pressing set clock 2 Adjust hours with and buttons AM PM toggles at 12 3 Press next 4 Adjust minutes with and buttons 5 Pre...

Отзывы: