background image

9

8. Repeat steps 1 - 7 and now check the various cycles for proper operation.

9.  Once the cycle operation has been verified, Place bypass valve in the normal operating mode  

(Fig. 1 on page 2)

 by opening the outlet bypass handle.   

10.  Go to laundry tub or bathtub faucet, preferably a faucet without an aerator and turn on the cold 

water, let the water run. Note the color of water coming from faucet. If discolored let water run until 

clear.

NOTE

:

 At no time should there be “large particles” of media noticed at faucet or laundry tub. If this is 

seen immediately shut off water and bypass system as this could be an indication of a distributor failure. 

Contact manufacturer or distributor for assistance.

 s

PeCifiCaTions

:

 

s

TarT

-

uP

 i

nsTruCTions

 

for

 W

aTer

 s

ofTeners

:

1

 All GPWS Series units are factory set for Medium Salt Setting. Note: influent waters must be at least 3 GPG hardness and 80 TDS.A calcite or corsex unit may  

  be needed for correct operation.

2

 Iron removal may vary depending on form of iron, pH and other local conditions. On waters that are pre-chlorinated or where other pre-oxidation occurs, an  

  iron precipitate can form that is too small to be filtered.

3

  The pH listed is the minimum for the influent water.

4

  Unit not tested for capacity at these flow rates. Water quality may vary.

Model 

GACS835

GACS1035

1

Capacity: 

(Grains/Lbs. 

NaCI)

Maximum

21,000 @ 9.0       

32,000 @ 15.0

Medium

18,000 @ 6.0    

28,400 @ 9.0     

Minimum

13,600 @ 3.0

23,600 @ 6.0   

Amount of Media (Cu. Ft.) 

0.66

1.0

Maximum Water Hardness (GPG)

50

75

2

Maximum Iron (PPM)

1

1

3

Minimum pH Required

7

7

4

Peak Flow Rate (GPM @ PSI)

12.2 @ 15.0

17.1 @ 15.0            

Continuous Flow Rate (GPM @ PSI)

5.8 @ 5.0

5.0 @ 2.8

Water Pressure Range (PSI)

30 - 100

30 - 100

Operating Temperature Range (˚F)

33 - 100

33 - 100

Electrical Requirements (volts-hertz)

110 - 50/60

110 - 50/60

Pipe Size

1”

1”

Total  Dimensions:          

Media Tank

13.5”(w) x 42.5”(h) 

13.5”(w) x 42.5”(h) 

Depth

22.5”

22.5”

Model 

GACS835

GACS1035

Min.

Gal.

Min.

Gal.

Brine Refill

3:51

2

5:51

3

Backwash

6

10

8

22

Brine & Rinse

40

16

60

24

Rapid Rinse

4

7

4

11

Total

54

35

78

60

Содержание GACS1035

Страница 1: ...Water Technologies Water Technologies Water Technologies Installation Instructions Owner s Manual Advance Cabinet Series Softeners...

Страница 2: ...Solids Over 10ppm may be harmful for human consumption Water conditioners do not remove nitrates or coliform bacteria this requires specialized equipment Greenway Water Conditioners are precision bui...

Страница 3: ...the exit are incorporated If desired two regenerations within 24 hours are possible with a return to the preset program To do a double regeneration 1 Press the regen button once regen today will flas...

Страница 4: ...to the building while not allowing water to exit from the system to the building Fig 3 This allows the service technician to draw brine and perform other tests without the test water going to the buil...

Страница 5: ...be used to unscrew the nut or cap Do not use a pipe wrench to tighten nuts or caps Do not place screwdriver in slots on caps and or tap with a hammer SITE REQUIREMENTS water pressure 30 100 psi curre...

Страница 6: ...f the control valve form a 7 loop at the discharge end of the line so that the bottom of the loop is level with the drain connection on the control valve This will provide an adequate anti siphon trap...

Страница 7: ...ss as calcium carbonate per gallon using the s or t buttons The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon can be increased if soluble iron needs to...

Страница 8: ...amming cont d 3 Manual Regeneration Sometimes there is a need to regenerate the system sooner than when the system calls for it usually referred to as manual regeneration There may be a period of heav...

Страница 9: ...ne tank filling and at no time during this process will you be without treated water 4 Power Loss If the power goes out for less than two hours the system will automatically reset itself If an extende...

Страница 10: ...de Fig 3 on page 2 CAUTION If water flows too rapidly it could result in loss of media to the drain When the water is flowing steadily to the drain without the presence of air slowly open the inlet va...

Страница 11: ...ay be needed for correct operation 2 Iron removal may vary depending on form of iron pH and other local conditions On waters that are pre chlorinated or where other pre oxidation occurs an iron precip...

Страница 12: ...ation time option in programming E control set at NORMAL on 0 E check with regeneration time option in programming 5 Error followed by code Error code 1001 unable to recognize start of regeneration Er...

Страница 13: ...and PC board power B no power at outlet B restore power C broken drive gear or drive cap assy C replace gear or drive cap assy D defective PC board D replace board 8 Valve does not regenerate automati...

Страница 14: ...o Part No Description Qty 1 YY WS CV3005 Spacer stack assembly 1 2 YY WS CV3004 Drive cap assembly 1 3 YY WS CV3135 O ring 228 1 4a YY WS CV3011 Piston assembly downflow 1 4b YY WS CV3011 01 Piston as...

Страница 15: ...ng 013 lower The injector plug and the injector each use one lower and one upper o ring REFILL PORT ASSEMBLY Item No Part No Description Qty 1 YY WS CV3195 01 Refill port plug assembly 1 2 YY WS CH461...

Страница 16: ...CV3162 010 1 0 DLFC for 3 4 elbow YY WS CV3162 013 1 3 DLFC for 3 4 elbow YY WS CV3162 017 1 7 DLFC for 3 4 elbow YY WS CV3162 022 2 2 DLFC for 3 4 elbow YY WS CV3162 027 2 7 DLFC for 3 4 elbow YY WS...

Страница 17: ...3 01 Meter plug assembly 1 SAFETY FLOAT ASSEMBLY Item No Part No Description 1 YY WS CH4650 01 474 safety elbow 3 8 2 YY WS CH4655 474 5 gpm flow control 3 YY WS CH4615 Elbow locking clip 4 YY WS CH46...

Страница 18: ...connect 2 2 YY WS CV3150 Split ring 2 3 YY WS CV3105 O ring 215 2 4 YY WS CV3145 Bypass rotor 1 2 5 YY WS CV3146 Bypass cap 2 6 YY WS CV3147 Bypass handle 2 7 YY WS CV3148 Bypass rotor seal retainer...

Страница 19: ...WS CV3189 Fitting 2 1 BRASS SWEAT Item No Part No Description Qty YY WS CV3007 02 1 brass sweat assembly 2 1 YY WS CV3151 Nut 1 quick connect 2 2 YY WS CV3150 Split Ring 2 3 YY WS CV3105 O ring 215 2...

Страница 20: ...teps as shown to the right To access this mode press set clock 1 Accessed by pressing set clock 2 Adjust hours with and buttons AM PM toggles at 12 3 Press next 4 Adjust minutes with and buttons 5 Pre...

Отзывы: