MAINTENANCE
63
500ze YM180 (12
−
2011)
VACUUM NOZZLE SKID
Check the vacuum nozzle skid for wear every 450
hours of operation. Replace the vacuum nozzle
skid when its thickness is 15 mm (0.60 in) or less.
CAST IRON SKID
Use the hex nut screws to adjust the wear plates
so the bottom edges are 19 mm (0.75 in) from the
ground. Ensure the cast iron skid is level with the
vacuum nozzle skid.
Check the cast iron skid for wear and damage
every 450 hours of operation.
SPRAY JETS
Clean the spray jet filters every 450 hours of
operation. A spray jet is located above each brush
and inside the vacuum tube.
Loosen the thumb screw to remove the spray jet
from the vacuum tube.
CLOUDMAKER
Check the CloudMaker weekly for damage and to
ensure it is functioning correctly.