OPERATION
48
500ze YM180 (12
−
2011)
CONDITIONS TABLE
The table below explains conditions that must be
met before certain operational functions will work.
Understanding how the different operational
functions work together will help the operator
more efficiently utilize the machine.
Conditions
Machine
ON
Mode Switch
Drive Switch
Hopper
Position
Park
Brake
Maximum Fan
Speed
Additional Conditions
Foot
−
notes
Function
Transit
Work 1
Work 2
FWD
N
REV
Hopper RAISE
X
X
X
X
50 rpm
Hopper Raise / Lower Switch:
RAISE
(1)
Hopper LOWER
X
X
X
X
X
Hopper Raise / Lower Switch:
LOWER
Work Mode 1
X
X
X
DOWN
OFF
Accelerator Pedal: Depressed
Speed: Up to 12 km/h (7.5 mph)
Work Mode 2
X
X
X
DOWN
OFF
Accelerator Pedal: Depressed
Speed: Up to 16 km/h (10 mph)
Transit Mode
X
X
X
DOWN
OFF
Accelerator Pedal: Depressed
Speed: Up to 32 km/h (20 mph)
(2)
Brushes ON
X
X
X
(3)
(4)
Vacuum Fan ON
X
X
X
DOWN
2700 rpm
Fan Door: CLOSED (11)
Brushes IN/OUT
X
X
X
Brushes/Nozzle UP
X
X
(5)
X
(5)
(5)
(5)
Brushes/Nozzle DOWN
X
X
X
(5)
(5)
Hopper Drain OPEN
X
X
X
Hopper Drain Switch: ON
CloudMaker /
Water Jets ON
X
X
X
Water Switch in Position 1 (7)
CloudMaker ON /
Water Jets OFF
X
X
X
Water Switch in Position 1 (12)
CloudMaker OFF /
Water Jets ON
X
X
X
Water Switch in Position 2 (7)
Wander Hose ON
X
X
X
DOWN
ON
Wander Hose Switch: ON
(3) (7)
Brake Lights ON
X
X
X
X
X
(9)
(9)
Transmission pressure less
than 20 bar (295 psi) (9)
Reverse Lights / Backup
Alarm ON
X
X
X
X
X
Pressure Washer ON
X
X
X
ON
Pressure Washer Switch: ON
(10)
Additional Notes:
(1)
If hopper is raised, machine speed is limited to 25% of normal speed. Accelerator pedal does not control machine speed in Work Mode 1 or 2.
(2)
Accelerator pedal directly controls machine speed when in Transit Mode.
(3)
Also required: Brush Speed Knob must be adjusted to proper level for function to operate. Function will not operate if knob is rotated fully counterclockwise.
(4)
The brush motors will continue to rotate for 6 seconds if machine moves out of Forward Work Mode 1
(5)
Brushes and Nozzle raise in Work Mode 1 if Drive Lever is in Neutral or Reverse.
(6)
Default machine speed is 2200 rpm in Work Mode 1 or 2, & 1200 rpm in Transit Mode.
(7)
Also required: Sufficient supply of water in water tank, In
−
cab water flow control knob OPEN, Pressure Washer Switch OFF. CloudMaker rotates in Work Mode 1,
even with Water Switch OFF.
Vacuum tube water jet is ON when Water Switch is in position 1 or 2. In
−
cab water flow control knob controls flow rate to brush jets ONLY.
(8)
Also required: Pressure Washer Switch OFF, Fan Door CLOSED.
(9)
Also required: Release Accelerator Pedal while travelling more than 6.5 km/h (4 mph). Pressing brake pedal activates Brake Lights.
(10)
Also required: Sufficient supply of water in water tank, Wander Hose Switch OFF.
(11)
Also required: Adjust Vacuum Fan Speed Knob for conditions.
(12)
Also required: Sufficient supply of water in water tank, In
−
cab water flow control knob CLOSED, Pressure Washer Switch OFF. CloudMaker rotates in Work Mode 1,
even with Water Switch OFF.