MAINTENANCE
53
500ze YM180 (11
−
2012)
HYDRAULICS
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, place drive
lever in neutral, and set parking brake.
Check the hydraulic fluid level daily while the
machine is at operating temperature.
1. Raise the hopper. See RAISING /
LOWERING THE HOPPER section of this
manual for additional information.
WARNING: Lift arm pinch point. Stay
clear of hopper lift arms.
2. Engage the hopper safety arm. See
ENGAGING THE HOPPER SAFETY ARM
section of this manual for additional
information.
WARNING: Raised hopper may fall.
Engage hopper safety arm.
3. Turn off the machine.
4. Remove the cap from the hydraulic reservoir
and check the fluid level.
ATTENTION! Do not overfill the hydraulic fluid
reservoir or operate the machine with a low
level of hydraulic fluid in the reservoir.
Damage to the machine hydraulic system may
result.
5. Apply a light film of hydraulic fluid onto the
filler cap gasket before reinstalling the cap
onto the reservoir.
6. After every 450 hours of operation, check the
hydraulic pressure filter indicator
7. Disengage the hopper support arm. See
DISENGAGING THE HOPPER SAFETY
ARM section of this manual for additional
information.
8. Lower the hopper. See RAISING /
LOWERING THE HOPPER section of this
manual for additional information.
HYDRAULIC HOSES
Check the hydraulic hoses after every 450 hours
of operation for wear, damage, and leaks.
FOR SAFETY: When servicing machine, use
cardboard to locate leaking hydraulic fluid
under pressure.
High pressure fluid escaping from a very small
hole can almost be invisible, and can cause injury.
Contact appropriate service personnel if a leak is
discovered. Do Not operate the machine.
ATTENTION!: Only use TENNANT supplied
hydraulic hoses or equivalent rated hydraulic
hoses.