Air to Water Heat Pump
Service Manual- Versati Series
DPOUSPM
11
S e t t i n g s t a r t d a t e o f d i s i n f e c t i o n
operation
0: Sunday
1: Monday
2: Tuesday
3: Wednesday,
4: Thursday
5: Friday
6: Saturday
0~6(default: 6)
12
S e t t i n g s t a r t t i m e i n 2 4 h o u r s o f
disinfection operation
00-00:00
01-01:00
…
23-23:00
0~23(default:23)
13
Enable/disable of Metal Base (pedestal)
heater
0: disable
1: enable
0~1(default:1)
14
Tank sensor quantity
1: one
2: two
1~2(default:2)
15
Tank equipment
0: NOT Equipped
1: Equipped
0~1(default: 0)
16
Other thermal equipment
0: NOT Equipped
1: Equipped
0~1(default: 0)
17
FCU equipment
0: NOT Equipped
1: Equipped
0~1(default: 0)
18
Remote air temperature sensor
0: NOT Equipped
1: Equipped
0~1(default: 0)
19
Heating operation level
0: high temperature cycle
1: low temperature cycle
0~1(default:1)
20
Setting turn on temperature of back-up
heater(indoor unit)
/
-20~18 (default: 0 )
21
S e t t i n g m a x i m u m w a t e r t a n k
temperature heated by heat pump cycle
/
40~50 (default: 50 )
22
S e t t i n g h e a t i n g t e m p e r a t u r e o f
disinfection operation
/
40~70 (default: 70 )
23
Setting lower temperature for Weather-
dependent operation
/
-20~5 (default: -15 )
24
Setting upper temperature for Weather-
dependent operation
/
10~20 (default: 15 )
25
Setting temperature gap from target
temperature of cooling operation
/
2~10 (default: 5 )
26
Setting temperature gap from target
temperature of heating operation
/
2~10 (default: 5 )
27
Setting temperature gap from target
t e m p e r a t u r e o f s a n i t a r y h e a t i n g
operation
/
2~8 (default: 3 )
3.2.3.4 Function Set-up Description
Function code 1: Setting temperature selection
7KHXQLWFDQRSHUDWHDFFRUGLQJWRDLUWHPSHUDWXUHRURXWÀRZZDWHUWHPSHUDWXUH7KHDLUWHPSHUDWXUHRU
RXWÀRZZDWHUWHPSHUDWXUHFDQEHVHOHFWHGDVVHWWLQJWHPSHUDWXUH
Note
: Air temperature as setting temperature is ONLY available when Remote Air Sensor Connection is
enabled and Function Code 18 is set as 01.
Function code 2:Forced operation
Forced Operation includes forced cooling and forced heating operation:
Forced cooling operation should be performed when additional refrigerant charge is required.
To charge the refrigerant, the unit must run in Cool mode.
)RUFHGFRROLQJVKRXOGEHSHUIRUPHGXSRQWKH¿UVWUXQWHVWUXQDQGZKHQRXWGRRUWHPSHUDWXUHLVORZHUWKDQ
Содержание VERSATI SERIES
Страница 1: ...AIR TO WATER HEAT PUMP SERVICE MANUAL VERSATI SERIES T1 R410A 50Hz 60Hz GC201202 ...
Страница 4: ...1 Air to Water Heat Pump Service Manual Versati Series PRODUCT QSPEVDU ...
Страница 15: ...12 Air to Water Heat Pump Service Manual Versati Series CONTROL DPOUSPM ...
Страница 66: ...63 Air to Water Heat Pump Service Manual Versati Series INSTALLATION JOTUBMMBUJPO ...
Страница 92: ...89 Air to Water Heat Pump Service Manual Versati Series JOTUBMMBUJPO GRS CQ16Pd Na H ...
Страница 102: ...99 Air to Water Heat Pump Service Manual Versati Series MAINTENANCE NBJOUFOBODF ...
Страница 128: ...125 Air to Water Heat Pump Service Manual Versati Series NBJOUFOBODF Fig 14 ...
Страница 129: ...126 Air to Water Heat Pump Service Manual Versati Series NBJOUFOBODF Indoor Unit 1 Front panel assy Fig 2 Fig 1 Fig 2 ...
Страница 148: ...145 Air to Water Heat Pump Service Manual Versati Series NBJOUFOBODF Ɣ Exploded View of GRS CQ16Pd Na H I ...
Страница 158: ...JF00300495 ...