98
Air to Water Heat Pump
Service Manual- Versati Series
JOTUBMMBUJPO
Ļ
Remote air temperature sensor should be installed where space heating is mainly applied;
ļ
After the Remote air temperature sensor is installed, should be set the value form “0”to“1” at the
function code 1 in the control panel, so as to select remote air temperature to the control point.
2.3.11 Thermostat
(1). GRS-CQ6.0Pd/Na-K(I), GRS-CQ8.0Pd/Na-K(I), GRS-CQ10Pd/Na-K(I), GRS-CQ12Pd/Na-K(I), GRS-
CQ14Pd/Na-K(I), GRS-CQ16Pd/Na-K(I), GRS-CQ12Pd/Na-M(I), GRS-CQ14Pd/Na-M(I), GRS-
CQ16Pd/Na-M(I)
26
25
24
21
22
23
XT3
Heat
N
Thermostat
Thermostat
L
(230V)
27
28
Cool
Heat
N
Cool
L
(24V)
Fig .1
Thermostat
Thermostat
26
25
24
21
22
23
XT3
Heat
N
L
(230V)
27
28
Heat
N
L
(24V)
Fig .2
(2). GRS-CQ16Pd/Na-H(I)
28
27
26
23
24
25
XT3
Heat
N
Thermostat
Thermostat
L
(230V)
29
30
Cool
Heat
N
Cool
L
(24V)
Fig .3
Thermostat
Thermostat
28
27
26
23
24
25
XT3
Heat
N
L
(230V)
29
30
Heat
N
L
(24V)
Fig .4
How to Wire Thermostat
(1). Uncover the front cover of the indoor unit and open the control box.
(2).
,GHQWLI\WKHSRZHUVSHFL¿FDWLRQRIWKHWKHUPRVWDWLILWLV9¿QGWHUPLQDOEORFN;7DV12aRU
12a2WKHUZLVHLILWLV9¿QGWHUPLQDOEORFN;7DV12aRU12a
(3). If it is Heating/Cooling thermostat, please connect wire as Fig 1 or Fig 3;
(4). If it is Heating only thermostat, please connect wire as Fig 2 or Fig 4;
CAUTION!
ķ
Never use 230V AC and 24V AC Thermostat at the same time, otherwise, it will cause short-circuit and
power cut-off by circuit breaker;
ĸ
Setting temperature by Thermostat(heating or cooling) should be chosen within the setting temperature
range of the product ;
Ĺ
For other constrains, please refer to previous page where constrains about remote air temperature
sensor
ĺ
Do not connect external electric loads, Wire (L) and (N) should be used only for operation Electric type
thermostat.
Ļ
Never connect external electric loads such as valves, fan coil units, etc. If connected, PCB of the indoor
unit can be seriously damaged.
ļ
Installation of Thermostat is very similar to that of Remote air temperature sensor.
Содержание VERSATI SERIES
Страница 1: ...AIR TO WATER HEAT PUMP SERVICE MANUAL VERSATI SERIES T1 R410A 50Hz 60Hz GC201202 ...
Страница 4: ...1 Air to Water Heat Pump Service Manual Versati Series PRODUCT QSPEVDU ...
Страница 15: ...12 Air to Water Heat Pump Service Manual Versati Series CONTROL DPOUSPM ...
Страница 66: ...63 Air to Water Heat Pump Service Manual Versati Series INSTALLATION JOTUBMMBUJPO ...
Страница 92: ...89 Air to Water Heat Pump Service Manual Versati Series JOTUBMMBUJPO GRS CQ16Pd Na H ...
Страница 102: ...99 Air to Water Heat Pump Service Manual Versati Series MAINTENANCE NBJOUFOBODF ...
Страница 128: ...125 Air to Water Heat Pump Service Manual Versati Series NBJOUFOBODF Fig 14 ...
Страница 129: ...126 Air to Water Heat Pump Service Manual Versati Series NBJOUFOBODF Indoor Unit 1 Front panel assy Fig 2 Fig 1 Fig 2 ...
Страница 148: ...145 Air to Water Heat Pump Service Manual Versati Series NBJOUFOBODF Ɣ Exploded View of GRS CQ16Pd Na H I ...
Страница 158: ...JF00300495 ...