U-Match Series Cassette Type Unit
33
WARNING!
After installing the panel, the insulated protective cover with the thickness of
1mm shall be used to wrap the wiring terminal, Tighten the insulated glue cover on
both sides with bonding tie to fix it.
(5) After connecting the communication wire, attach the flannelette on the
foam to prevent the communication wire from reaching out the electric
raceway(for GUD50T/A1-K).
3.3 Electrical Installation
3.3.1 Requirement and Notice on Electrical Installation
WARNING:
The electrical installation for the air conditioner should observe the following
requirements:
①
.
The electrical installation must be conducted by professionals in
compliance with local laws and regulations and the instructions in this
manual. Never extend the power cord. The electric circuit must be
equipped with a circuit breaker and air switch both with sufficient capacity.
②
.
The unit’s operating power must be within the nominal range stated in the
instruction manual. Use a specialized power circuit for the air conditioner.
Do not draw power from another power circuit.
③
.
The air conditioner circuit should be at least 1.5m away from any
inflammable surface.
④
.
The external power cord, connection wire of indoor and outdoor units and
Содержание U-Match GU100T/A1-K