DC Inverter U-match Series Floor Ceiling Type Unit
35
(5) Installing the Drain Pipes
1) For determining the position of the drain
hose, perform the following procedures.
2) Insert the drain pipe to the drain outlet of
the unit and then tighten the clamp
securely with tape.
3)
Connect the extension drain pipe to the
drain pipe and then tighten the clamp with
tape.
Insulate the pipe clamp and the drain
hose using heat insulation sponge.
①
.
- Metal clamp
②
.
- Drain hose
③
.
- Grey tape
Tighten the clamp until the screw head
is less than 4 mm from the hose.
①
.
- Metal clamp
②
.
- Insulation sponge
4) When drain hose requires extension, obtain an extension hose
commercially available.
5) After connecting the local drain hose, tape the slits of the heat
insulation tube.
6) Connect the drain hose to the local drain pipe. Position the inter