DC Inverter U-match Series Floor Ceiling Type Unit
24
3.2.3 Connection Pipe Installation
3.2.3.1 Installation Notice and Requirement on Connection Pipe
NOTICE
①
Indoor unit adopts special joints that can’t be disassembled. The installation
method is the same as the unit with ordinary joints. However, because the
joints can’t be removed, if the connection is not good and causes leakage, the
joints need to be cut and welded again for replacement.
②
The removal-proof screw nut must be connected to the indoor unit.
Installation method: Connect the connection pipes first to the indoor
unit and then to the outdoor unit. When bending a connection pipe, be
careful not to damage the pipe. Do not over-tighten the screw nut,
otherwise leakage will occur. Besides, the outside of connection pipe
should be added with a layer of insulating cotton to protect it from
mechanical damage during installation, maintenance and
transportation.