DC Inverter U-match Series Floor Ceiling Type Unit
12
(9) Install the outdoor unit at a place where condensate can be easily
drained.
3.1.3 Unit Dimension
WARNING
(1) Install the indoor unit in a location which can withstand a load of at least five
times the weight of the main unit and which will not amplify sound or vibration.
(2) If the installation location is not strong enough, the indoor unit may fall and
cause injuries.
(3) If the job is done with the panel frame only, there is a risk that the unit will come
loose. Please take care.
(1)
Indoor Unit
NOTICE
Drilling of ceiling opening and installation of air conditioner must be performed by
professionals!
Unit
:
mm
Dimensions
Model
A
B
C
D
H
GUD35ZD/A-T
870
235
812
318
665
GUD50ZD/A-T
870
235
812
318
665
GUD71ZD/A-T
1200
235
1142
318
665