30
GMV-Pdhm1630W4/Na-M
GMV-Pdhm280W/Na-M
;
GMV-Pdhm450W/Na-M
;
GMV-Pdhm450W/Na-M
;
GMV-Pdhm450W/Na-M
Φ
25.4
Φ
54.1
Φ
41.3
GMV-Pdhm1700W4/Na-M
GMV-Pdhm400W/Na-M
;
GMV-Pdhm400W/Na-M
;
GMV-Pdhm450W/Na-M
;
GMV-Pdhm450W/Na-M
Φ
25.4
Φ
54.1
Φ
41.3
GMV-Pdhm1750W4/Na-M
GMV-Pdhm400W/Na-M
;
GMV-Pdhm450W/Na-M
;
GMV-Pdhm450W/Na-M
;
GMV-Pdhm450W/Na-M
Φ
25.4
Φ
54.1
Φ
41.3
GMV-Pdhm1800W4/Na-M
GMV-Pdhm450W/Na-M
;
GMV-Pdhm450W/Na-M
;
GMV-Pdhm450W/Na-M
;
GMV-Pdhm450W/Na-M
Φ
25.4
Φ
54.1
Φ
41.3
Note:
1
)
For outdoor unit with total rated capacity less than 20.0kW
If the length from outdoor unit to the farthest indoor unit is equal to or longer than 50m, bigger pipes
shall be used as the liquid-side main pipe and the high and low pressure gas main pipes from outdoor unit to
the first branch pipe of indoor unit. The max. diameter shall not be more than
Φ
54.1mm.
2
)
For outdoor unit with total rated capacity more than or equal to 20.0kW and less than 60.0kW
If outdoor unit is a single-unit system or a single-module system, and if the length from outdoor unit to
the farthest indoor unit is longer than 70m, bigger pipes shall be used as the liquid-side main pipe and the
high and low pressure gas main pipes from outdoor unit to the first branch pipe of indoor unit. The max.
diameter shall not be more than
Φ
54.1mm.
If outdoor unit is a module parallel system, and if the length of the first branch pipe of outdoor unit to the
farthest indoor unit is longer than or equal to 70m, bigger pipes shall be used as the liquid-side main pipe
and the high and low pressure gas main pipes from the first branch pipe of outdoor unit to the first branch
pipe of the indoor unit. The max. diameter shall not be more than
Φ
54.1mm.
3
)
For outdoor unit with total rated capacity more than 60.0.0kW
If outdoor unit is a single-unit system or a single-module system, and if the length from outdoor unit to
the farthest indoor unit is longer than 90m, bigger pipes shall be used as the liquid-side main pipe and the
high and low pressure gas main pipes from outdoor unit to the first branch pipe of indoor unit. The max.
diameter shall not be more than
Φ
54.1mm.
If outdoor unit is a module parallel system, and if the length of the first branch pipe of outdoor unit to the
farthest indoor unit is longer than or equal to 90m, bigger pipes shall be used as the liquid-side main pipe
and the high and low pressure gas main pipes from the first branch pipe of outdoor unit to the first branch
pipe of the indoor unit. The max. diameter shall not be more than
Φ
54.1mm.