GREE
GMV5 INDOOR UNIT SERVICE MANUAL
37
Model
GMV-N50G/C9A-D GMV-N56G/C9A-D GMV-N63G/C9A-D GMV-N71G/C9A-D
*Maximum fuse current
A
6
6
6
6
Sound pressure level
dB(A)
44
44
44
44
Power supply
208-230V~60Hz
Piping
interface
Liquid pie
mm
Φ6.35
Φ9.52
Φ9.52
Φ9.52
Gas pipe
mm
Φ12.7
Φ15.9
Φ15.9
Φ15.9
Drain pipe
Outer diameter
×Wall thickness
mm
Φ20×1.5
Φ30×1.5
Φ30×1.5
Φ30×1.5
Dimensions
W×D×H
mm
940×200×298
1008×221×319
1008×221×319
1008×221×319
Net weight
Main body
kg
12.5
15.0
15.0
15.0
Model
GMV-N22G/E3A-D GMV-N28G/E3A-D GMV-N36G/E3A-D GMV-N45G/E3A-D
Horse Power
HP
1
1
1.5
2
Cooling capacity
kW
2.2
2.8
3.6
4.5
Heating capacity
kW
2.5
3.2
4.0
5.0
Air volume
m
3
/h
500
500
630
630
Cooling power input
W
50
50
60
60
Cooling current input
A
0.2
0.2
0.21
0.21
Heating power input
W
50
50
60
60
Heating current input
A
0.2
0.2
0.21
0.21
*Minimum line current
A
0.25
0.25
0.38
0.38
*Maximum fuse current
A
6
6
6
6
Sound pressure level
dB(A)
38
38
44
44
Power supply
208-230V~60Hz
Piping
interface
Liquid pie
mm
Φ6.35
Φ6.35
Φ6.35
Φ6.35
Gas pipe
mm
Φ9.52
Φ9.52
Φ12.7
Φ12.7
Drain pipe
Outer diameter
×Wall thickness
mm
Φ20×1.5
Φ20×1.5
Φ20×1.5
Φ20×1.5
Dimensions
W×D×H
mm
843×180×275
843×180×275
940×200×298
940×200×298
Net weight
Main body
kg
10.0
10.0
12.5
12.5
Model
GMV-N50G/E3A-D GMV-N56G/E3A-D GMV-N63G/E3A-D GMV-N71G/E3A-D
Horse Power
HP
2
2
3
3
Cooling capacity
kW
5.0
5.6
6.3
7.1
Heating capacity
kW
5.8
6.3
7.0
7.5
Air volume
m
3
/h
630
750
750
750
Cooling power input
W
60
70
70
70
Cooling current input
A
0.21
0.31
0.31
0.31
Heating power input
W
60
70
70
70
Heating current input
A
0.21
0.31
0.31
0.31
*Minimum line current
A
0.38
0.5
0.5
0.5
*Maximum fuse current
A
6
6
6
6
Sound pressure level
dB(A)
44
44
44
44
Power supply
208-230V~60Hz
Piping
interface
Liquid pie
mm
Φ6.35
Φ9.52
Φ9.52
Φ9.52
Gas pipe
mm
Φ12.7
Φ15.9
Φ15.9
Φ15.9
Drain pipe
Outer diameter
×Wall thickness
mm
Φ20×1.5
Φ30×1.5
Φ30×1.5
Φ30×1.5
Dimensions
W×D×H
mm
940×200×298
1008×221×319
1008×221×319
1008×221×319
Net weight
Main body
kg
12.5
15.0
15.0
15.0
Содержание CM100N1320
Страница 1: ...Multi Variable Air Conditioners Indoor Units GC201809 VI...
Страница 6: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 1 PRODUCT...
Страница 50: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 45 CONTROL...
Страница 51: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 46 1 Operation Flowchart...
Страница 91: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 86 INSTALLATION...
Страница 136: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 131 Maintenance...
Страница 151: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 146 GMV ND160PHS A T GMV ND224PH A T GMV ND280PH A T...
Страница 276: ...JF00302966...