128
Installation and Maintenance
Service Manual
Appendix:
Appendix 1: Reference Sheet of Celsius and Fahrenheit
Set temperature
Conversion formula for Fahrenheit degree and Celsius degree: Tf=Tcx1
.
8+32
Ambient temperature
Fahrenheit
display
temperature
(℉)
Fahrenheit
(℉)
Celsius
(℃)
Fahrenheit
display
temperature
(℉)
Fahrenheit
(℉)
Celsius
(℃)
Fahrenheit
display
temperature
(℉)
Fahrenheit
(℉)
Celsius
(℃)
32/33
32
0
55/56
55.4
13
79/80
78.8
26
34/35
33.8
1
57/58
57.2
14
81
80.6
27
36
35.6
2
59/60
59
15
82/83
82.4
28
37/38
37.4
3
61/62
60.8
16
84/85
84.2
29
39/40
39.2
4
63
62.6
17
86/87
86
30
41/42
41
5
64/65
64.4
18
88/89
87.8
31
43/44
42.8
6
66/67
66.2
19
90
89.6
32
45
44.6
7
68/69
68
20
91/92
91.4
33
46/47
46.4
8
70/71
69.8
21
93/94
93.2
34
48/49
48.2
9
72
71.6
22
95/96
95
35
50/51
50
10
73/74
73.4
23
97/98
96.8
36
52/53
51.8
11
75/76
75.2
24
99
98.6
37
54
53.6
12
77/78
77
25
Fahrenheit
display
temperature
(℉)
Fahrenheit
(℉)
Celsius
(℃)
Fahrenheit
display
temperature
(℉)
Fahrenheit
(℉)
Celsius
(℃)
Fahrenheit
display
temperature
(℉)
Fahrenheit
(℉)
Celsius
(℃)
61
60.8
16
69/70
69.8
21
78/79
78.8
26
62/63
62.6
17
71/72
71.6
22
80/81
80.6
27
64/65
64.4
18
73/74
73.4
23
82/83
82.4
28
66/67
66.2
19
75/76
75.2
24
84/85
84.2
29
68
68
20
77
77
25
86
86
30
Appendix 2: Configuration of Connection Pipe
1.Standard length of connection pipe
(
More details please refer to the specifications
)
2.Min length of connection pipeFor the unit with standard connection pipe of 5m, there is no limitation for themin length of
connection pipe. For the unit with standard connection pipe of 7.5m and 8m, the min length of connection pipe is 3m.
3.Max length of connection pipe
(
More details please refer to the specifications
)
4.The additional refrigerant oil and refrigerant charging required after prolonging connection pipe
● After the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5ml of refrigerant oil for
each additional 5m of connection pipe.
● The calculation method of additional refrigerant charging amount (on the basis of liquid pipe):
● Basing on the length of standard pipe, add refrigerant according to the requirement as shown in the table. The additional
refrigerant charging amount per meter is different according to the diameter of liquid pipe. See Sheet 2.
● Additional refrigerant charging amount = prolonged length of liquid pipe X additional refrigerant charging amount per meter
Additional refrigerant charging amount for R32
Diameter of connection pipe
Indoor unit throttl
Outdoor unit throttle
Liquid pipe(inch)
Gas pipe(inch) Cooling only,cooling
and heating(g / m) Cooling only(g / m) Cooling and heating(g / m)
1/4''
3/8'' or 1/2''
16
12
16
1/4'' or 3/8''
5/8'' or 3/4''
40
12
40
1/2''
3/4'' or 7/8''
80
24
96
5/8''
1'' or 1 1/4''
136
48
96
3/4''
/
200
200
200
7/8''
/
280
280
280
Note: The additional refrigerant charging amount in Sheet 2 is recommendedvalue, not compulsory.
Содержание CB385001000
Страница 1: ...Service Manual Change for life GREE ELECTRIC APPLIANCES INC OF ZHUHAI...
Страница 30: ...27 Technical Information Service Manual 873 376 330 5 555 GWH24AGD K6DNA1C O CB385W08603 Unit mm...
Страница 116: ...113 Installation and Maintenance Service Manual GWH18AGD K6DNA1A O...
Страница 117: ...114 Installation and Maintenance Service Manual...
Страница 118: ...115 Installation and Maintenance Service Manual...
Страница 119: ...116 Installation and Maintenance Service Manual Capillary Sub assy...
Страница 121: ...118 Installation and Maintenance Service Manual screws Rear Grill...
Страница 122: ...119 Installation and Maintenance Service Manual...
Страница 123: ...120 Installation and Maintenance Service Manual...
Страница 124: ...121 Installation and Maintenance Service Manual...
Страница 125: ...122 Installation and Maintenance Service Manual...