107
Installation and Maintenance
Service Manual
Holder
Connector
Step
Procedure
5.Remove panel
a
Remove 3 screws fixing evaporator assy.
At the back of the unit, Loosen the clasp of the
connection pipe clamp and then remove the
connection pipe clamp.
First remove the left side of evaporator from
the groove of bottom shell and then remove
the right side from the clasp on the bottom
shell.
Adjust the position of connection pipe on
evaporator slightly and then lift the evaporator
upwards to remove it.
b
c
d
Connecting
pipe clamp
Screws
clasp
Conncetion pipe