Malfunction
Name
Display Method of Indoor Unit
A/C status
Possible Causes
Dual-8
Code
Display
Indicator Display (during
blinking, ON 0.5s and OFF
0.5s)
Operation
Indicator
Cool
Indicator
Heating
Indicator
19
Decrease
frequency
due to
high air
discharge
F9
All loads operate normally, while
operation frequency for
compressor is decreased
Overload or temperature is too high;
Refrigerant is insufficient;
Malfunction of electric expansion valve (EKV)
20
Limit/
decrease
frequency
due to
antifreezing
FH
All loads operate normally, while operation
frequency for compressor is decreased
Poor air-return in indoor unit or fan speed is too
low
21
Voltage for
DC bus-bar
is too high
PH
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop operation.
1. Measure the voltage of position L and N on
wiring board (XT), if the voltage is higher than
265VAC, turn on the unit after the supply voltage is
increased to the normal range.
2.If the AC input is normal, measure the voltage of
electrolytic capacitor C on control panel (AP1), if
its normal, theres malfunction for the circuit, please
replace the control panel (AP1)
22
Voltage of
DC bus-bar
is too low
PL
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
1. Measure the voltage of position L and N on
wiring board (XT), if the voltage is higher than
150VAC,
turn on the unit after the supply voltage is
increased to the normal range.
2.If the AC input is normal, measure the voltage of
electrolytic capacitor C on control panel (AP1), if
its normal, theres malfunction for the circuit, please
replace the control panel (AP1)
23
Compressor
Min
frequence in
test state
P0
Showing during min. cooling or min. heating test
24
Compressor
rated
frequence in
test state
P1
Showing during nominal cooling or nominal heating
test
25
Compressor
maximum
frequence in
test state
P2
Showing during max. cooling or max. heating test
Содержание CB385001000
Страница 1: ...Service Manual Change for life GREE ELECTRIC APPLIANCES INC OF ZHUHAI...
Страница 30: ...27 Technical Information Service Manual 873 376 330 5 555 GWH24AGD K6DNA1C O CB385W08603 Unit mm...
Страница 116: ...113 Installation and Maintenance Service Manual GWH18AGD K6DNA1A O...
Страница 117: ...114 Installation and Maintenance Service Manual...
Страница 118: ...115 Installation and Maintenance Service Manual...
Страница 119: ...116 Installation and Maintenance Service Manual Capillary Sub assy...
Страница 121: ...118 Installation and Maintenance Service Manual screws Rear Grill...
Страница 122: ...119 Installation and Maintenance Service Manual...
Страница 123: ...120 Installation and Maintenance Service Manual...
Страница 124: ...121 Installation and Maintenance Service Manual...
Страница 125: ...122 Installation and Maintenance Service Manual...