Uneven seed
spacing
Hydraulic drive meter motor rpm too
low for reliable control by proportional
valve
Increase field speed. See “
page 2.
Ensure correct seed disk is installed. Refer to Material
Rate manual.
Excessive field speed
Reduce field speed to recommended values. See
“
Partially plugged row unit seed tube Remove any obstruction.
Uneven seed
depth
Excessive field speed
Reduce field speed to recommended values. See
“
Field conditions too wet
Wait for improved field conditions.
Seed firmer not in correct position
and/or incorrect tension setting
Ensure correct positioning and adjust tension as needed.
See “
Incorrect row unit down pressure
Adjust row unit down pressure. See “
Excessive debris and/or uneven field
conditions
Rework field.
Seed depth too
shallow and/or
scattered seed
Damaged seed tube
Replace seed tube.
Opener depth too shallow
Adjust side depth wheels. See “
Excessive seed
cracking
Incorrect disk cell size for seed
Use correct seed disks for seed type and size. Refer to
Material Rate manual.
Seed size may be too small or too large, refer to Material
Rate manual.
Damaged, old, or dry seed.
Replace with clean seed.
Seed blowing
Fan rpm too high
Slow down the fan to 2800 rpm. See “
Seal to airbox not positioned properly Inspect and adjust seal. Seal should be intact, and
compress to about 1/2 inch (13 mm) under seed container.
Replace, if necessary.
Seed hoses
plugging or
partially
plugging
Fan too slow/high
Inspect seed hoses, and remove obstructions, in these areas:
between airbox and y-tubes,
between y-tubes and meter, and
meter and seed tube.
Adjust fan speed. See “
Sag or kink in seed hoses
Inspect seed hoses, and remove obstructions, in these areas:
between airbox and y-tubes,
between y-tubes and meter, and
meter and seed tube.
Ensure proper air hose placement at mount weldment. If
correct, shorten the length of air hoses as necessary.
Meter and/or y-tubes are closed
Open meter door and/or y-tubes.
Incorrect seed hose assembly
placement
Properly attach y-tube to intended meter.
Possible air leak
Inspect for air leaks from fan to top of meter. Repair or
replace, as necessary.
Problem
Cause
Solution
Содержание PL5200
Страница 12: ...Great Plains 411 825M 12 07 2020 5 PL5200 Planter Table of Contents Index Safety Information ...
Страница 46: ...Great Plains 411 825M 12 07 2020 39 PL5200 Planter Table of Contents Index Twin Row to Single Row ...
Страница 62: ...Great Plains 411 825M 12 07 2020 55 PL5200 Planter Table of Contents Index Adjustments ...
Страница 66: ...Great Plains 411 825M 12 07 2020 59 PL5200 Planter Table of Contents Index Options ...
Страница 78: ...Great Plains 411 825M 12 07 2020 71 PL5200 Planter Table of Contents Index Maintenance ...
Страница 86: ...Great Plains 411 825M 12 07 2020 79 PL5200 Planter Table of Contents Index Troubleshooting ...
Страница 96: ...Great Plains 411 825M 12 07 2020 89 PL5200 Planter Table of Contents Index Specifications ...
Страница 104: ...Great Plains 411 825M 12 07 2020 97 PL5200 Planter Table of Contents Index Option Installation ...
Страница 106: ...Great Plains 195 612M 12 07 2020 99 26 Foot 2 Section Drill Table of Contents Index Warranty ...
Страница 108: ...Great Plains 411 825M 12 07 2020 101 PL5200 Planter Table of Contents Index ...
Страница 109: ...Table of Contents Index ...
Страница 110: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402 ...