![GRAVOGRAPH L-SOLUTION 100 Ex Fibre Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/gravograph/l-solution-100-ex-fibre/l-solution-100-ex-fibre_user-manual_2258787020.webp)
L-SOLUTION 100 Ex Fibre machine
. 20
First contact
Electrical connections of the machine
Stand behind the machine.
Exhaust
system
Installation
1. Plug in the input/output machine-exhaust system connection cable
, first to the exhaust
system, then to the LASER machine. Tighten the connectors screws using the screwdriver (3.5).
The connectors screws must be very tight to avoid accidental disconnection of the cables
while the machine is turned on as this could permanently damage the electronic cards
(label
).
Before making any user standard inputs/outputs connections you must check that
the electric and electronic features of the different inputs and outputs are respected
(see "the Automaton function" described in the chapter "System operation" page 68).
A bad connection can irreparably damage the electronics of your machine.
2. Plug in the user standard inputs/outputs connection cable to the LASER machine
if you use
the Automaton function described in the chapter "System operation" (see page 68).
The use of the function Automaton means that the engraving machine cannot be considered
individually to ensure the safety of the operator.
The engraving machine is actually integrated into a global process (the automated
production line).
Consequently, it is the final work station (engraving m aut loading robot)
that must comply with the regulations in terms of safety.
The person who fits the engraving machine within the manufacturing process is therefore
responsible for the EC compliance of the final work station.
3. Plug in the electric cable
, first to the engraving LASER machine, then to the mains supply.