PDR 100 Fibre Channel Installation
58
PDR 100 Fibre Channel Installation
Installing the Fibre Channel Board
The Fibre Channel board must be installed in slot J15, adjacent to the Master EDR
board. To install the Fibre Channel board, refer to Figure 14 and Figure 15
(page 52) for location, and Figure 18 (page 57) for installation information and
proceed as follows:
1. Slip the Fibre Channel board into the board slide at the front of the board area
for slot J15 aligning it with the edge-board connectors in the motherboard at
the bottom panel and the rear panel cutout for J15.
2. Ensure that the board contacts are correctly aligned with the motherboard
connectors and firmly press down on the board until it is fully seated. Screw
holes in the board bracket should align with the two bracket mounting screw
holes, one on the inside and one on the outside of the rear panel.
3. Use the Torx tool with the T15 bit to secure the Fibre Channel board bracket
to the rear panel with the two screws provided, but do not fully tighten until
after the PCI Interconnect board has been installed.