KayakDD-1 Digital Production Switcher
7.4.5
CPLD Update Trouble Shooting
7.4.5.1
Inconsistent EEPROM Data
When the software installation process checks whether an CPLD update is necessary
or not, it initiates a plausibility check of the EEPROM data of each hardware board. If
the EEPROM data is not plausible the user is notified and the update will not be
initiated.
Figure 30
Error Message during CPLD update
The CPLD update can be performed manually at any time. An update even tries to
correct inconsistent EEPROM data. Nevertheless an manually CPLD update should
always be done by qualified service engineers or experienced users only!
7.4.5.2
Wrong Position of CPLD Program Switch
There is a switch (ETX. BSCAN) on each hardware board that controls external or
internal programming of the CPLD. If this switch is set to
ON
the CPLD can’t be
updated by the software installation process. In this case the user is informed by an
error message (“
CPLD update failed: validating chain failed, check test switch
(EXT. BSCAN)”
) and the update process will be terminated. If this happens contact
your service engineers.
To bring the system back to normal operation mode, perform a reset.
Planning and Installation Manual
73
Содержание KayakDD-1
Страница 8: ...KayakDD 1 Digital Production Switcher Planning and Installation Manual 7 ...
Страница 9: ...KayakDD 1 Digital Production Switcher 8 Planning and Installation Manual ...
Страница 11: ...KayakDD 1 Digital Production Switcher 10 Planning and Installation Manual ...
Страница 15: ...KayakDD 1 Digital Production Switcher 14 Planning and Installation Manual ...
Страница 33: ...KayakDD 1 Digital Production Switcher 32 Planning and Installation Manual ...
Страница 89: ...KayakDD 1 Digital Production Switcher 88 Planning and Installation Manual ...
Страница 90: ...KayakDD 1 Digital Production Switcher Planning and Installation Manual 89 ...