4-9
Chapter 4 REGISTRATION MARK SETTINGS AND DETECTION
4.5 Setting the Registration Mark Size
This function allows you to specify the size of the registration marks drawn on the medium.
(1) Press the
[PAUSE] key
to select PAUSE mode.
(2) Press the
[NEXT] key
repeatedly untl the followng menu s dsplayed.
FORCE
OFFSET
SPEED
QUALITY
MARK TOOL U/D
BUFFER CLR. VIEW
(3) Press the
[F1] key
(MARK) to dsplay the regstraton mark functons selecton menu.
FORCE
OFFSET
SPEED
QUALITY
MODE DIST ADJ
TYPE OTHER SETUPS
(4) Press the
[F4] key
(OTHER SETUPS) to dsplay the menu shown below.
FORCE
OFFSET
SPEED
QUALITY
SIZE ADJ. SENS
ORG OFT SENS OPT
(5) Press the
[F1] key
(SIZE) to display the menu for setting the registration mark size.
FORCE
OFFSET
SPEED
QUALITY
MARK SIZE
15 mm
Use the
[ ]
or
[ ]
key
to change the numerc value, and then press the
[ENTER] key
to confirm your selection.
Setting range: 5 to 20 (mm)
Registration mark pattern 1,
Mirror 1
Registration mark pattern 3
Registration mark pattern 2,
Mirror 2
Set value
Set value
Set value
Set value
Set value
Set value
(6) Press the
[PAUSE] key
to cancel PAUSE mode.
Содержание FC2250 Series
Страница 1: ...USER S MANUAL MANUAL NO FC2250 UM 151 FC2250 SERIES CUTTING PRO...
Страница 105: ...5 29 Chapter 5 FUNCTION SETTINGS AND OPERATIONS Cutting Plotting Conditions List...
Страница 111: ...CHAPTER 6 TROUBLESHOOTING PRODUCT SUMMARY 6 1 Troubleshooting 6 2 Error Messages...
Страница 117: ...CHAPTER 7 VACUUM SUCTION PRODUCT SUMMARY 7 1 Selecting the Vacuum Pump 7 2 Installation Location 7 3 Vacuum Pump Wiring...
Страница 121: ...CHAPTER 8 SPECIFICATIONS PRODUCT SUMMARY 8 1 Main Specifications 8 2 External Dimensions...
Страница 130: ......