Gate operator frequenCy of use
this gate operator is rated for
Residential and light industRial use
Only
, which is a maximum of five households or ten carpark spaces for a
commercial building. any more than this and the life span of the operator can
be reduced.
the warrantee does not cover wear and tear due to average use of more
than 60 operations per day.
if higher frequency of use is required consider using an industrial sliding gate
operator rated for continuous use. gates that have a lot of users are more likely
to be struck by a vehicle so need to be a robust industrial grade operator.
battery back up system
if a Battery Back up is used the 24v 7ah battery takes over if the mains power
fails. it will provide up to 200 operations over a couple of days or last a week
or so if not used.
battery conditioning during normal use
during normal use when the motor starts up it draws power from the battery,
which keeps it conditioned for reliable operation as batteries need to be used
regularly for them to work properly.
low Voltage power cable
the Battery conditioning arrangment also allows the power transformer to be
away from the gate and low voltage power cable only run to the gate. this is
because any current that is too high for the low voltage cable is taken up by the
battery. this means that the operator
must have a battery connected
before
it will work properly with low voltage cabling.
solar powered
run from the Battery during normal use, which is charged from a solar panel.
the 14ah battery supplied will run for up to 12 to 24 operations per day depend-
ing on the weight of the gate for 10 cloudy days in a row. a 20watt solar panel
will charge the battery from flat in two days of full sun. if you are in an area that
doesn’t get a lot of sun you may need to add extra solar panels and batteries,
which are available as extra’s.