11
type and size OF cable
For accessories
0.4mm diameter (0.12mm2) or 0.65mm diameter (0.33mm2) outdoor telephone
cable is ideal for connecting photocells, digital keypads and intercoms as this
cable has a tough outer sheath and is gel filled to protect it from moisture. cat
5 and indoor phone cable is fine to use so long as it isn’t exposed to moisture
for prolonged periods. if using security cable this must be a conduit that is fully
sealed to prevent any exposure to moisture other wise it can rot in the ground.
240V mains at gate
mains power is best hard wired to the operator. if an outdoor power point is
used the can be turned off so is not recommended. you will need a registered
electrician to do this for you.
low Voltage systems
don’t need a register electrican because all power at the gate is 24v. a plug in
transformer is supplied that can plug in anywhere there is power or can be hard
wired by an electrician. low voltage garden lighting cable only is required
between the transformer and the gate operator. 2mm
2
cable is good for up to
25m and 4mm
2
for up to 50m.