Linear Burner Inserts Automated Operation
3.2
Gas and Electric Requirements
Input Voltage
120 VAC / 60 Hz to Grand Effects
®
Control
Panel
Output Voltage
24Vac or 12Vac (each unit requires less than
3 amperes)
Gas Type
Natural
Propane
Gas Pressure (Nominal)
7” wc
11” wc
3.2.1
GAS FLOW REQUIREMENTS
Length
36”
48”
60”
72”
84”
96”
108”
120”
BTU/Hr
120,000
120,000
120,000
120,000
120,000
120,000
120,000
120,000
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause injury, property damage or
death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this
equipment. Do not install near any combustibles such as
wood structures, fuels, clothing, fabrics or dry vegetation.
Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water. Leaking LP-
gas may cause a fire or explosion if ignited causing serious
bodily injury or death. A LP gas regulator should never be
installed under the Linear Fire Pit. It should be installed
by a gas expert in a remote location away from the heat
source. Check with your gas supplier to verify gas flows
and pressures available at the location of your installation.
In many cases utility companies will install larger meters
at no charge to accommodate larger flows. Propane, as for
the purpose of this standard means a hydrocarbon product
meeting the CGSB Specification CAN/CGSB-3.14. Call
manufacturer for setup on high altitude installations.