PILOT MOUNT PLATE

PILOT COVER

SUPPORT PLATE

LINEAR BURNER

DEFLECTOR

Z-CLIP

WITH 1/4-20 BOLT

LINEAR BURNER ASSEMBLY

NOTE: The pilot end of the Linear Burner must be

             positioned nearest the Sub Panel.

Figure 6.  Linear Burner Assembly Components

9.  Mount the Support Plate using the L Brackets provided. The Support 

Plate should be mounted so that top of Burner is 1/2”-1” below top of 
wall or cap as shown in Figures 12 and 19. The Support Plate should 
rest on top of the L Brackets.

10.  If the inside trough dimensions (width x length) are larger than 

suggested dimensions. Then builder will need to support Burner 
Assembly with cross member supports. The extra gap around burners 

will need to be filled in with expanded or perforated stainless metal so 

that decorative media does not fall through as shown in Fig. 20.

 CAUTION

In order to minimize risk of fire which could result in property 

damage or serious injury including death, do not used solid plate 

because it will not allow burner cavity to vent, which will cause 

overheating.

11.  On commercial installations, it is recommended to install a keyed 

switch and kill switch located in close proximity and in visible sight of 
feature or features. The keyed and kill switches are supplied by others.

12.  Inner Mount Subpanel should be mounted on vertical end wall that is 

closest to pilot. This will allow access for service.

13.  Connect inlet and outlet gas hoses supplied by Grand Effects

®

making sure all connections are tight. Keep hoses and wires away 
from underside of Support Plate. They must be kept away from the hot 
undersurface of the burner.

14.  Connect ignitor and ground wires at pilot to Subpanel.

Содержание LIAUT24xxIM

Страница 1: ...death Improper installation and or operation can create carbon monoxide gas and flue gases which can cause serious injury property damage or death For installations in the vicinity of occupied living...

Страница 2: ...cts Linear Burners 6 3 1 Preparing the Linear Burner for Installation 6 3 2 Gas and Electric Requirements 7 3 3 Construction of Burner Cavity 8 3 4 Installing the Linear Burner 9 3 5 Installing the Su...

Страница 3: ...Technical Support at 800 822 7933 U S or Grand Effects at 949 697 5270 DANGER RISK OF ELECTRICAL SHOCK OR ELECTROCUTION This fire pit linear burner must be installed by a licensed or certified electri...

Страница 4: ...in a location with good drainage Dimensions to construct burner cavities are shown in Figures 1 and 2 Ventilation is a requirement and must be built into structure as shown in Figures 17 and 21 WARNI...

Страница 5: ...IDE MOUNT For Outer Mount do not run burner wires in tight space do not run wires through dirt or encase in concrete or tight fitting conduit They need to be loose and in open space or they will not w...

Страница 6: ...installing or servicing the bowl Failure to do so could result in death or serious injury to serviceman pool or spa users or others due to electrical shock 3 1 Preparing the Linear Burner for Install...

Страница 7: ...fitting and set aside 3 Use two 2 1 2 sealing rings on the gas piping for bonding Securely thread the first sealing ring to the bottom of the pipe threads then wrap with bonding wire and thread on the...

Страница 8: ...s clothing fabrics or dry vegetation Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the...

Страница 9: ...GE 8 2 5 Dia 9 feet 132 x 13 135 x 13 5 x 20 Brackets provided by GE 10 2 5 Dia 10 feet 144 x 13 147 x 13 5 x 20 Brackets provided by GE 10 2 5 Dia Table 1 Required Dimensions for Burner Cavity Inner...

Страница 10: ...ergency 1 Install the control panel and gas piping as shown in Figure 1 Natural Gas Figure 2 Propane Gas or Figure 3 Commercial Installation Gas lines must be clean and free from any dirt debris or co...

Страница 11: ...ANE GAS OUTLET 12 VAC IN CONDUIT UNDERGROUND 3 4 1 GAS PIPING UNDERGROUND PROPANE ADDER SUPPLIED BY GRAND EFFECTS 120 VAC 60HZ INPUT TO CONTROL PANEL MANUAL GAS VALVE JUNCTION BOX 12 VAC 12VAC Figure...

Страница 12: ...he sides of the structure 7 Venting the air gap at the bottom end walls and structure is required for safety measures and cooling the electrical components as shown in Figures 4 and Figure 5 MULTIPLE...

Страница 13: ...with expanded or perforated stainless metal so that decorative media does not fall through as shown in Fig 20 CAUTION In order to minimize risk of fire which could result in property damage or serious...

Страница 14: ...ECTRICAL TO PILOT IGNITOR 24 VAC FROM CONTROL PANEL GAS OUTLET TO PILOT GAS OUTLET TO LINE BURNER RED GRN GRN GRD RED 2 RED 2 GRN 4 FEET MAXIMUM LENGTH Sub Panel Dimensions 11 5 in W x 11 5 in H IMPOR...

Страница 15: ...burner GAS LINE PIPE SIZING NOTE Gas line pipe should be sized based upon distance from the source to the burner number of elbows and BTU of burner Use the reference charts from the latest version of...

Страница 16: ...TRICAL AT PILOT SIDE OF BURNER CAVITY Figure 12 Burner Cavity Inner Mount Side view VENTS VENTS VENTS GAS AND ELECTRICAL CONDUITS TO BURNER VENTS DRAINAGE REQUIRED FOR NATURAL GAS ONLY LENGTH SEE CHAR...

Страница 17: ...Diagram Outer Mount Natural Gas 120 VAC Control Relay or Switch by others Grand E ects Control Panel Gas Supply Source 12 VAC to Grand E ects Sub Panel Gas Supply to Sub Panel Outside Burner Cavity N...

Страница 18: ...ROL PANEL GAS SUPPLY FROM SOURCE LOCATE GAS AND ELECTRICAL AT SUB PANEL DRAINAGE Natural Gas Only DRAINAGE Natural Gas Only GRAND EFFECTS BURNER L BRACKET 1 2 1 Figure 19 Burner Cavity Outer Mount Sid...

Страница 19: ...of the burner support and burner assembly Larger lava rock is recommended 2 4 in size It will work better than smaller rock Make sure that all rock is clear of the pilot area and hood area Pilot hood...

Страница 20: ...should be no power at the burner assemblies when purging propane The propane adder valve should remain wired and energized when purging After purging is complete make sure the area is vented and free...

Страница 21: ...connections are tight The units should be cycled frequently especially after a rain The burner assembly will not work in snow and ice conditions The burner assembly should be covered and protected fr...

Страница 22: ...e and at your own risk Before any inspection of the unit always turn off power and gas supply at the control panel If you experience problems with this unit call Grand Effects or a licensed heating pr...

Страница 23: ...tom Corrective Action Main burner does not light no spark 1 Remove rock glass away from pilot area Look for small pieces obstructing pilot 2 If still no spark confirm that you have 12VAC out of the pa...

Страница 24: ...ross pilot 2 If using glass make sure an open pilot hood is used Remove rock glass away from pilot area Does it get better How much glass Thin down glass on burner assembly 3 Remove all rock glass fro...

Страница 25: ...TH EARTH GROUND SUB PANEL GRN RED WHT TERMINAL STRIP IN GRAND EFFECTS CONTROL PANEL NOTES FEEDER CIRCUIT PROTECTION PROVIDED BY OTHERS TORQUE TERMINAL BLOCKS TO 12 0 13 LB IN USE STRANDED COPPER CONDU...

Страница 26: ...Page 26 Linear Burner Inserts Automated Operation NOTES...

Страница 27: ...Linear Burner Inserts Automated Operation Page 27 NOTES...

Страница 28: ...used under license All other trademarks are the property of their respective owners H0660700 REV A Zodiac Pool Systems LLC 2882 Whiptail Loop 100 Carlsbad CA 92010 1 800 822 7933 www ZodiacPoolSystem...

Отзывы: