Section 5 - Lubrication & Maintenance
5-34
80804002
100 Hours
Replace Hydraulic Reservoir Breather
1. Perform shutdown procedure on page 3-14 or page 3-33.
2. Locate reservoir breather
(1)
mounted on hydraulic tank
(2)
.
3. Depress breather plunger
(3)
to relieve hydraulic reservoir pressure.
4. Spin reservoir breather counter-clockwise to remove from tee
(4)
.
5. Spin replacement reservoir breather clockwise to attach to tee.
100
OAC2050
OW1030
OAC1970
2
4
3
1