Repair
24
3A8047B
Remove Air Motor
, page 9.
2. Disconnect displacement pump from air motor. See
steps 2 and 3 under
3. Disconnect sensor cable, air line, and ground wire
from air motor.
4. Remove mounting screws (5) and washers (4)
holding air motor (2 or 3) to mounting bracket.
5. Refer to your XL Air Motor manual to service or
repair the air motor.
6. Reconnect ground wire and sensor cable. Follow
steps in reverse order to reinstall air motor.
Drum Feed RAM Pump
Assembly (Feed Module)
NOTE:
See Drum Feed RAM Pump assembly (227) in
parts breakdown beginning on page 45.
See your Supply Systems manual for service and repair
instructions and parts.
Flush Pump
2. Disconnect pump inlet line (154) and air lines (57,
60) from flush pump.
3. Disconnect fluid outlet line.
4. Remove four screws (153) that attach flush
pump (8) to bracket (152) and remove flush pump.
5. Refer to your Merkur Pump Assembly manual to
service or repair flush pump 257463.
6. Follow steps in reverse order to reinstall flush
pump.
F
IG
. 3
WLD
2 or 3
5
4
Bracket
57
153
8
60
154
152
Содержание XM PFP 273231
Страница 38: ...Parts 38 3A8047B Base System 262878 page 2 of 5 Set air regulator to 80 psi 550 kPa 5 5 bar WL D D F E...
Страница 46: ...Parts 46 3A8047B WL D...
Страница 64: ...Dimensions 64 3A8047B Dimensions WL E WL D FP LQ FP LQ FP LQ FP LQ FP LQ FP LQ FP LQ FP LQ FP LQ...
Страница 67: ...Notes 3A8047B 67 Notes...