Repair
3A8047B
15
Replace USB Module
1.
Remove Shroud and Front Panel of Control Box
see page 14.
2. Disconnect CAN cables and USB cable from USB
module (519).
3. Remove two mounting screws from USB module
and remove module from base.
4. Follow steps in reverse order to install new USB
module.
.
Replace Fluid Control Module (FCM)
NOTE:
The USB module does not need to be removed
prior to replacing the FCM.
1.
Remove Shroud and Front Panel of Control Box
see page 14.
2. Remove all cables from FCM (518). Take note of
cable locations.
3. Loosen four mounting screws (535).
4. Slide FCM up and out of keyhole slots.
5. Follow steps in reverse order to install new FCM.
7. Most of the system configuration is stored in the
FCM. Use the display to change the configuration
to the values in the old FCM. See XM PFP
operation manual for instructions.
Replace Alarm
1.
Remove Shroud and Front Panel of Control Box
see page 14.
2. Disconnect alarm wires from alarm (517).
3. Unscrew alarm (517) and replace.
4. Screw in new alarm. Reconnect alarm wires.
5. Reinstall front panel of control box and reinstall
shrouds.
519
518
535
535
517
Содержание XM PFP 273231
Страница 38: ...Parts 38 3A8047B Base System 262878 page 2 of 5 Set air regulator to 80 psi 550 kPa 5 5 bar WL D D F E...
Страница 46: ...Parts 46 3A8047B WL D...
Страница 64: ...Dimensions 64 3A8047B Dimensions WL E WL D FP LQ FP LQ FP LQ FP LQ FP LQ FP LQ FP LQ FP LQ FP LQ...