Repair
3A8047B
21
Dosing Valve Assembly
1. Follow
2. Disconnect all fluid lines from dosing valves (28 or
29). See F
3. Remove two bolts (31) securing dosing valve to
bracket.
4. Unscrew dosing valve nipple fitting (36 or 37) from
dosing valve outlet.
5. Disconnect pressure sensor (831) from dosing
valve. See page 56.
6. Remove dosing valves.
7. See
Ratio Control Valve Assemblies (28, 29)
on
page 56 for disassembly illustration.
8. Follow steps in reverse order to reassemble dosing
on page 56 for assembly
illustration and specifications.
F
IG
. 2: Dosing Valve Assembly
29
28
55
55
54
85
31
37
36