Maintenance
28
313431K
9.
Run the end of hose (B), through the hose guide (G)
and then the hole (E) in reel (F
. 24).
10. For air/water or oil reel, attach hose end (B) to
hose reel swivel (A). Then carefully remove
C-Clamp (D) (F
IG
. 11).
11. For grease reel, insert hose end (B) through
bracket (H). Attach hose end (B) to strain relief hose
(J).
12. Pull the hose hard (B) enough to release the latch
and slowly allow the hose to retract.
13. If used, reassemble hose reel enclosure following
procedure described on page 21.
14. Flush system.
To avoid contaminating the fluid with line-scale,
chips or other installation debris, before installing
meter or dispense valve to end of hose, flush the
equipment with a compatible solvent such as Stod-
dard solvent or mineral spirits.
a.
Secure the end of the hose in a waste bucket.
b.
Blow out entire lubricant supply line with air.
c.
Pump solvent through line until fluid runs clear
and is debris free.
d.
Pump lubricant through line until all solvent is
flushed out.
15. Position hose stop (D) so hose extends far enough
for all operators to reach dispensing valve. Securely
tighten nuts (bb) to keep hose stop in place.
16. Install meter or dispense valve to end of hose follow-
ing instructions provided with the dispense equip-
ment.
17. Adjust spring tension, page 19.
F
IG
. 24
C
B
D
E
G
F
ti13190
A
B
C
E
F
G
Grease reel
ti13190-2
Air/Water or Oil reel
J
H
ti13190-3
NOTICE
Do not bypass mounting bracket H. Failure to attach
the hose through mounting bracket H can cause
decreased retraction performance.