Installation
313431K
19
Increasing and Decreasing Spring Tension
Single Pedestal HP Model Hose Reels
Increasing Spring Tension
1.
Pull out hose, 1 to 2 turns and engage latch.
2.
Pull hose back through hose rollers.
3.
Wrap a loop of hose onto the reel flange.
4.
Check the spring tension; the hose must pull out
fully and retract fully. Wrap more loops, one at a
time around the reel flange until the spring has the
desired tension.
NOTE: Do not put so many loops onto the reel that the
spring winds up tightly before the hose is fully extended.
Decreasing Spring Tension
Remove loops to decrease tension.
•
The hose reel spring is not a serviceable part. Do
not attempt to replace or service the hose reel
spring.
•
The spring is always under great tension and could
be propelled with enough force to cause serious
injury.
•
Never allow reel to spin freely. Doing so causes the
hose reel to spin out of control, which could cause
serious injury if you are hit by the hose valve or
other moving parts.
•
Reel must be bolted securely in place when mak-
ing adjustments.