Operator Controls
◆
Operator Station
310633C
27
*
If a potlife alarm (code E3) occurs, you must purge the system with solvent or spray new mixed material before
the alarm can be fully cleared.
F
IG
. 27
•
For additional information about alarms, see Alarm Troubleshooting, page 51.
•
The number of colors available when scrolling with the
or
keys is determined during software setup.
See page 32.
•
Color 0 can be selected to purge the system (as an alternative to Purge
key) on multiple color units.
Refer to page 32.
Color change and alarm indicator
• Normally displays color number.
• If an alarm occurs, displays an alarm code,
E1 to E9.
• Color number displays after alarm is cleared.
Color change sequence indicator (green LED)
• Stays lit while a color is in use.
• Shuts off when
or
keys are pressed.
• If a new color is entered, the LED blinks while the color is loaded
and turns solid after loading is complete.
• A new color is selected by pressing
or
then pressing
.
Error Clear
• Red LED stays lit
when error occurs
or blinks for a potlife
alarm
• LED shuts off after
alarm is cleared &
key is pushed.*
Report
• Sends report to
printer and resets A
and B totalizers.
• Green LED blinks
once after key is
pressed.
Mix
• Starts Mix mode.
• Green LED remains
lit while in Mix
mode.
• LED blinks when 2
minute idle time is
exceeded.
Up
Scrolls color numbers
up.
Down
Scrolls color numbers
down.
Enter
Enters selected color
and starts color
change sequence.
Standby
• Starts Standby mode.
• Green LED remains lit
while in Standby mode.
Purge
• Starts Purge mode.
• Green LED blinks during purge
sequence and turns solid once purge is
complete. LED turns off when another
mode is started.