Power Requirements
The ProMix™ II operates with 85-250 VAC, 50/60 Hz
input power, with a maximum of 2 amp current draw.
The power supply circuit must be protected with a 15
amp maximum circuit breaker.
Not included with system:
•
Power supply cord compatible to your local power
configuration. Wire gauge size must be 8-14 AWG.
•
Bulkhead strain relief sized for 22.4 mm (0.88 in.)
hole that will hold the power supply cord in the
EasyKey™ Display port
(V). F
1.
Provide power to the EasyKey™ Display. Use con-
duit to protect wiring.
2.
Install the strain relief and power cord or conduit
bulkhead through the EasyKey™ Display port
(V). F
. 14.
3.
See F
IG
. 21 for the L1, L2, and ground wiring con-
nections inside the EasyKey™ Display.
4.
Ground the Display to a true earth ground. See
Grounding, page 23.
Connect EasyKey™ Display to
Smart Fluid Panel
There are two 50 ft.(15.2 m) cables to route between the
EasyKey™ Display and Smart Fluid Panel: the Fluid
Panel Power Cable (A) and the Fiber Optic Cable (C).
1.
Connect the appropriate Fluid Panel Power Cable
(A) end to the EasyKey™ Display connector
.
. 14.
2.
Connect the other cable end to the Smart Fluid
Panel connector
(B). F
IG
. 15.
3.
The Fiber Optic Cable (C) is shipped from the fac-
tory attached to the EasyKey™ Display connector
. 14.
•
All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
•
Enclose all cables routed in the spray booth
and high traffic areas in conduit to prevent
damage from paint, solvent, and traffic.
•
All options ordered on the ProMix™ II system
are electrically tested at the factory.
F
IG
. 14
If you need to detach the Fiber Optic Cable (C)
from the EasyKey Display, note how the cable is
routed inside the enclosure. Ensure that the door
can swing open and close without catching or pull-
ing wires.