20
308783
Startup
f.
Release the component A valve
key to
close the valve.
g.
Hold down the component B
valve key to open the component
B valve. Trigger the gun into a
grounded waste container until
component B flows from the gun.
h.
Release the component B valve
key to
close the valve.
13. Clear the lines of unmixed material by purging with
solvent.
a.
Press the return key
〈↵
) to move to level 1
setup.
X
b.
Adjust the solvent
fluid supply pressure
(X). Use the lowest
pressure possible to
avoid splashing.
c.
Hold down the solvent valve key
to open
the solvent valve.
d.
Trigger the gun into a grounded waste con-
tainer until solvent flows from the nozzle.
e.
Release the solvent valve
key to close the
valve.
f.
Touch the token to the setup contacts to exit
setup mode.
14. Prime the lines with mixed material.
a.
Turn the operator switch to mix.
7476A
b.
Trigger the gun into a grounded waste con-
tainer until mixed material flows from the
nozzle.
c.
Turn the operator switch to
standby.
7475A