10
308783
Installation
Setup
1.
Tighten the fluid line connections between the flow
meter, mix manifold, and other system compo-
nents as they may have loosened during shipment.
2.
Mount the ProMix control (C). See Fig. 2. Make
sure the mounting surface can support the weight
of the control and any hoses and accessories
connected to it and any stress that may be applied
during operation.
3.
Install the beaker tray (58) with the two screws,
and place the beakers (61) in the tray.
C
KEY
C
ProMix Control
58 Beaker Tray
61 Beaker
61
A
F
D
E
C
B
58
Dimensions,
inches (mm)
A
B
C
D
E
F
14.6
(370.8)
24
(609.6)
16
(406.4)
16
(406.4)
10
(254)
4.5
(114.3)
Fig. 2
7488A
4.
Screw the air filter (51) into the purge air inlet
.
See Fig. 3.
5.
Install a shut-off valve (J
-1
) into the air filter (51) to
shut off the air to the mix manifold.
6.
Install a shut-off valve (J
-2
) into the control air
inlet
to shut off the air to the control.
7.
Connect two separate air lines to the two control
air inlets.
a.
Connect an air line to the shut-off valve (J
-1
).
NOTE:
This line supplies the air for the mix man-
ifold solvent/air purge sequence.
Fig. 3
KEY
A
Component A Inlet
B
Component B Inlet
S
Solvent Inlet
Control Air Inlet (top)
Purge Air Inlet (bottom)
J
-1
Shut-off Valve for
Purge Air
J
-2
Shut-off Valve for Con-
trol Air
51
Air Filter
J
-2
J
-1
51
7489A