Check that the component A and B fluid supply
pressure (X) is properly set for your application. Do
not exceed the controller’s 3000 psi (21 MPa, 207
bar) maximum working fluid pressure or 4000 psi
(28 MPa, 276 bar) maximum working fluid pres-
sure with kit 239954 installed.
X
03096A
Y
03096A
10. Check that the fluid valves
(Y) are open.
Air Shutoff Valve
11. Shut off the air at the spray gun.
12. Prime the system.
CAUTION
Do not use the first 4 to 5 oz. (120 to 150 ml) of
material from the system, as it may not be thor-
oughly mixed due to alarms while priming the sys-
tem.
NOTE:
If the flow meters overrun because of air in the
system, operation will stop. See
Alarm Troubleshoot-
ing
on page 28.
a.
Touch the token (on the back of the reference
card) to the setup contacts (Z). Number 1
appears on the display, indicating the control is
at level 1 setup.
Z
Setup Level
b.
Refer to the reference card, and press the
return key
〈↵
) on the keypad twice to move to
level 3 setup.
c.
3 appears on the display, indicating that the
system is at level 3 setup, and the light under
the first icon lights up.
d.
Refer to the reference card and
hold down the component A valve
key to open the component A
valve.
ÄÄÄ
ÄÄÄ
e.
Trigger the gun into
a grounded waste
container until com-
ponent A flows from
the gun.