34
308783
Service
Removing and Installing the Meters
1.
Relieve the pressure as instructed on page 17.
2.
Turn off the power to the control (air and/or electri-
cal).
3.
Remove the front cover (2). See Fig. 12.
4.
Disconnect the three fluid lines from the check
valves (13). See Fig. 14.
5.
Loosen the four screws (21), and slide out the fluid
panel (4). See Fig. 14 and 15.
6.
Disconnect the meter fluid lines (16, 46, and/or
17, 45).
7.
Disconnect the wire harness (94) from the meter
electronic sensor.
8.
Remove the screws (68) from the back of the
meter (20), and remove the meter.
9.
Repair the meter as instructed in the separate
meter manual.
10. Secure the meter (20) to the control cabinet with
the screws (68).
11. Connect the wire harness (94) to the meter elec-
tronic sensor.
12. Connect the meter fluid lines (16, 46, and/or
17, 45).
13. Push in the fluid panel (4) and secure it with the
screws (21).
14. Connect the fluid lines to the check valves (13).
15. Install the front cover (2). See Fig. 12.
Fig. 14
13
4
21
7490A
Fig. 15
4
20
68
7495A
45
94
17
46
16