Motor Control Board Diagnostics
32
3A2817A
SmartControl
The SmartControl contains stored data to assist with
troubleshooting and maintenance. To view this stored
data on the digital display:
1.
Relieve pressure
, page 9.
2.
Plug in sprayer.
3.
Hold down display button and turn sprayer ON.
4.
Release display button about 1 second after turning
on sprayer.
Pro 230ES displays (model family) for a few sec-
onds and then data point 1 is displayed.
5.
Push display button and next data point displays.
6.
Turn sprayer OFF and then ON to exit stored data
mode.
Data Point
Definition
1
•
Number of hours power switch has been ON with power applied. (Pro 230ES only)
•
Serial Number of sprayer. (Pro 270ES only)
2
Number of hours motor has been running.
3
Last error code. Press and hold display button to clear error code to E=00
4
Software revision
Содержание Pro 230ES