Troubleshooting
16
3A2817A
Sprayer quits after spraying for 5 to
10 minutes.
Basic Electrical Problems, page 11
of Troubleshooting.
Perform necessary procedures.
Electrical supply volt meter. Meter
must read 86-130 VAC for 120V
models.
If voltage is too high, do not operate
sprayer until corrected.
Tightness of pump packing nut.
Over tightening tightens packings
on rod, restricts pump action, and
overloads motor.
Loosen packing nut. Check for leak-
ing around throat. Replace pump
packings, if necessary. See pump
manual.
Type of Problem
What to Check
(if check is OK, go to next)
What to DO
(When check is not OK, refer to
this column