Troubleshooting (ES 1000 & ES 2000)
3A4603F Operation, Repair, Parts
67
Sprayer does not run at all
Check the connections. Control
is not receiving a motor position
sensor signal
1.
Turn power OFF.
2.
Disconnect motor position sensor and inspect for
damage at connectors.
3.
Reconnect sensor.
4.
Turn power ON. If code continues, replace motor.
Control board status light blinks
16 times repeatedly
Sprayer does not run at all
Check voltage supply to the sprayer
(sprayer plugged into wrong
voltage)
1.
Set sprayer to OFF and disconnect power to
sprayer.
2.
Locate a good voltage supply to prevent damage to
electronics.
3.
See
Control board status light blinks
17 times repeatedly
TYPE OF PROBLEM
WHAT TO CHECK
HOW TO CHECK
ti18685a